Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/241867
Type: Artigo
Title: Assessment of volume and height of the coronoid process in patients with different facial types and skeletal classes: a cone-beam computed tomography study
Author: Gomes, Amanda Farias
Nejaim, Yuri
Brasil, Danieli Moura
Groppo, Francisco C.
Ferreira Caria, Paulo H.
Neto, Francisco Haiter
Abstract: Purpose: To determine the height and volume of the mandibular coronoid process (CP) by cone-beam computed tomography (CBCT) and to identify the presence of any correlations of these measurements with age, gender, facial type, and skeletal class. Materials and Methods: The sample consisted of 132 patients from a departmental routine patient base. After CBCT, CP height was determined using OnDemand 3D software (CyberMed, Seoul, Republic of Korea), and CP volume was obtained using ITK-SNAP 3.0 software (Cognitica, Philadelphia, PA). Measurements were subjected to analysis of covariance against facial type, skeletal class, gender, and age, with a significance level of 5%. Results: CP height and volume were similar regardless of age, facial type, and skeletal class. However, the 2 measurements were statistically different regarding gender, with larger values for men than for women. Conclusions: These observations suggest that gender is the only factor influencing the height and volume of the CP. (C) 2015 American Association of Oral and Maxillofacial Surgeons
To determine the height and volume of the mandibular coronoid process (CP) by cone-beam computed tomography (CBCT) and to identify the presence of any correlations of these measurements with age, gender, facial type, and skeletal class. The sample consisted of 132 patients from a departmental routine patient base. After CBCT, CP height was determined using OnDemand 3D software (CyberMed, Seoul, Republic of Korea), and CP volume was obtained using ITK-SNAP 3.0 software (Cognitica, Philadelphia, PA). Measurements were subjected to analysis of covariance against facial type, skeletal class, gender, and age, with a significance level of 5%. CP height and volume were similar regardless of age, facial type, and skeletal class. However, the 2 measurements were statistically different regarding gender, with larger values for men than for women. These observations suggest that gender is the only factor influencing the height and volume of the CP
Subject: Músculo masseter
Adulto
Country: Estados Unidos
Editor: Elsevier
Citation: Assessment Of Volume And Height Of The Coronoid Process In Patients With Different Facial Types And Skeletal Classes: A Cone-beam Computed Tomography Study. W B Saunders Co-elsevier Inc, v. 73, p. JUL-2015.
Rights: fechado
Identifier DOI: 10.1016/j.joms.2015.02.020
Address: http://www.sciencedirect.com/science/article/pii/S0278239115002050
Date Issue: 2015
Appears in Collections:FOP - Artigos e Outros Documentos

Files in This Item:
File SizeFormat 
000356306900030.pdf608.94 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.