Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/107576
Type: Artigo de periódico
Title: Synthesis And Application Of Imprinted Polyvinylimidazole-silica Hybrid Copolymer For Pb 2+ Determination By Flow-injection Thermospray Flame Furnace Atomic Absorption Spectrometry
Author: Tarley C.R.T.
Andrade F.N.
de Oliveira F.M.
Corazza M.Z.
de Azevedo L.F.M.
Segatelli M.G.
Abstract: A novel ion imprinted polyvinylimidazole-silica hybrid copolymer (IIHC) was synthesized and used as a selective solid sorbent for Pb 2+ ions preconcentration using an on-line solid phase extraction (SPE) system coupled to TS-FF-AAS. The ionic hybrid sorbent was prepared using 1-vinylimidazole and 3-(trimethoxysilyl)propylmethacrylate as monomers, Pb 2+ ions as template, tetraethoxysilane as reticulating agent and 2,2'-azobis-isobutyronitrile as initiator. The best on-line SPE conditions concerning sorption behavior, including sample pH (6.46), buffer concentration (9.0mmolL -1), eluent (HNO 3) concentration (0.5molL -1) and preconcentration flow rate (4.0mLmin -1), were optimized by means of full factorial design and Doehlert matrix. The analytical curve ranged from 2.5 to 65.0μgL -1 (r=0.999) with limit of detection of 0.75μgL -1; the precision (repeatability) calculated as relative standard deviation (n=10) was 5.0 and 3.6% for Pb 2+ concentration of 10.0 and 60.0μgL -1, respectively. From on-line breakthrough curve, column capacity was 3.5mgg -1. Preconcentration factor (PF), consumptive index (CI) and concentration efficiency (CE) were 128.0, 0.16mL and 25.6min -1, respectively. The selective performance of the sorbent, based on relative selectivity coefficient, was compared to NIC (non imprinted copolymer) for the binary mixture Pb 2+/Cd 2+, Pb 2+/Cu 2+ and Pb 2+/Zn 2+. The results showed that ion imprinted polyvinylimidazole-silica hybrid polymer had higher selectivity for Pb 2+ than NIC at 64.9, 16.0 and 8.8 folds. The developed method was successfully applied for highly sensitive and selective Pb 2+ determination in different kinds of water samples, parenteral solutions and urine. Accuracy was also assessed by analyzing certified reference fish protein (DORM-3) and marine sediment (MESS-3 and PACS-2) with satisfactory results. © 2011 Elsevier B.V.
Editor: 
Rights: fechado
Identifier DOI: 10.1016/j.aca.2011.07.029
Address: http://www.scopus.com/inward/record.url?eid=2-s2.0-80052270555&partnerID=40&md5=786f4a672308cbce03ce03285b3da34d
Date Issue: 2011
Appears in Collections:Unicamp - Artigos e Outros Documentos

Files in This Item:
File SizeFormat 
2-s2.0-80052270555.pdf475.72 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.