Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/106755
Type: Artigo de evento
Title: Fault Current Test Of A Bifilar Bi-2212 Bulk Coil
Author: Baldan C.A.
Shigue C.Y.
Filho E.R.
Abstract: A bifilar Bi-2212 bulk coil with parallel shunt resistor was tested under fault current condition using a 3 MVA singlephase transformer in a 220 V-60 Hz line achieving fault current peak of 8 kA. The fault current tests are performed from steady state peak current of 200 A by applying controlled short circuits up to 8 kA varying the time period from one to six cycles. The test results show the function of the shunt resistor providing homogeneous quench behavior of the HTS coil besides its intrinsic stabilizing role. The limiting current ratio achieves a factor 4.2 during 5 cycles without any degradation. © 2008 IEEE.
Editor: 
Rights: fechado
Identifier DOI: 10.1109/TASC.2008.920595
Address: http://www.scopus.com/inward/record.url?eid=2-s2.0-45149094056&partnerID=40&md5=a96b63bc3b5e8bd62566da0fdf2361f0
Date Issue: 2008
Appears in Collections:Unicamp - Artigos e Outros Documentos