Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/103909
Type: Artigo de periódico
Title: Influence Of A Cobalt-chromium Metal Framework On Surface Roughness And Knoop Hardness Of Visible Light-polymerized Acrylic Resins
Author: De Souza Jr. J.A.
Rodrigues Garcia R.C.M.
Moura J.S.
Del Bel Cury A.A.
Abstract: Although visible light-polymerized acrylic resins have been used in removable partial dentures, it is not clear whether the presence of a metal framework could interfere with their polymerization, by possibly reflecting the light and affecting important properties, such as roughness and hardness, which would consequently increase biofilm accumulation. The aim of this study was to compare the roughness and Knoop hardness of a visible light-polymerized acrylic resin and to compare these values to those of water-bath- and microwave-polymerized resins, in the presence of a metal framework. Thirty-six specimens measuring 30.0 x 4.0 ± 0.5 mm of a microwave- (Onda Cryl), a visible light- (Triad) and a water-bath-polymerized (Clássico) (control) acrylic resins containing a cobalt-chromium metal bar were prepared. After processing, specimens were ground with 360 to 1000-grit abrasive papers in a polishing machine, followed by polishing with cloths and 1-μm diamond particle suspension. Roughness was evaluated using a profilometer (Surfcorder SE 1700) and Knoop hardness (Kg/mm 2) was assayed using a microhardness tester (Shimadzu HMV 2000) at distances of 50, 100, 200, 400 and 800 μm from the metal bar. Roughness and Knoop hardness means were submitted to two-way ANOVA and compared by Tukey and Kruskal Wallis tests at a 5% significance level Statistically significant differences were found (p<0.05) for roughness and Knoop hardness, with light-polymerized resin presenting the highest values (Ra = 0.11 μm and hardness between 20.2 and 21.4 Kg/mm 2). Knoop values at different distances from the metal bar did not differ statistically (p>0.05). Within the limitations of this in vitro study, it was concluded that the presence of metal did not influence roughness and hardness values of any of the tested acrylic resins.
Editor: 
Rights: aberto
Identifier DOI: 
Address: http://www.scopus.com/inward/record.url?eid=2-s2.0-33747858081&partnerID=40&md5=b79ee1a75c276113834a9362a8171b06
Date Issue: 2006
Appears in Collections:Unicamp - Artigos e Outros Documentos

Files in This Item:
File Description SizeFormat 
2-s2.0-33747858081.pdf64.59 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.