Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/103782
Type: Artigo de periódico
Title: Comparing Forced Air Cooling And Water Cooling For Apples
Author: Silva F.
Goyette B.
Bourgeois G.
Vigneault C.
Abstract: The duration of precooling is an important factor in the design of any precooling system. Water and air precooling systems are recommended for apples; however, the literature does not present any specific data to help designers choosing between these two systems. Two lab-scale precooling systems were built to allow a comparison of the respective performances of water and air used as heat sink fluids in apple cooling. The water system was shown to perform twice as fast as the air system under comparable conditions. It was also discovered that the half cooling time of apples precooled with water or with air could be predicted as a function of their diameter using regression equations developed during the present study.
Editor: 
Rights: fechado
Identifier DOI: 
Address: http://www.scopus.com/inward/record.url?eid=2-s2.0-33845406205&partnerID=40&md5=1ebdcf3a8729842525c2f527901f36b2
Date Issue: 2006
Appears in Collections:Unicamp - Artigos e Outros Documentos

Files in This Item:
File Description SizeFormat 
2-s2.0-33845406205.pdf272.07 kBAdobe PDFView/Open