Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/101730
Type: Artigo de periódico
Title: Qualitative And Quantitative Comparison Between Images Obtained With Filtered Back Projection And Iterative Reconstruction In Prostate Cancer Lesions On 18f-fdg Pet
Author: Etchebehere E.C.S.C.
Macapinlac H.A.
Gonen M.
Humm J.
Yeung H.W.D.
Akhurst T.
Scher H.I.
Larson S.M.
Abstract: Background. Recently, iterative reconstruction with segmented attenuation corrections (IRSAC) has been introduced for reconstruction of 18F-FDG PET images. IRSAC produces images that are more pleasing to the eye, but qualitative and quantitative comparisons between IRSAC and filtered back projection (FBP) have not been reported for metastatic cancer. Since quantitative data has been widely used as an adjunct to interpretation of PET scans, comparison between IRSAC and FBP is needed. The purpose of this study was to compare image quality and the maximum standardized uptake value (SUVmax) obtained with FBP and with IRSAC in metastatic lesions from prostate cancer. Methods. Twenty 18F-FDG PET scans (10 baseline and 10 follow-up) were performed in 10 patients with prostate cancer (ages 66-85 yrs, mean 73.6 yrs). Acquisition began 45 min after injection of 370 MBq of 18F-FDG. Images were reconstructed using FBP and IRSAC, and submitted to visual and quantitative analysis. SUVmax was obtained for all metastases, on FBP and IRSAC. A Jaszczak phantom study was also performed. Results. IRSAC images showed better image quality than FBP especially in regions of high activity concentrations. IRSAC detected 106 lesions on both baseline and follow-up scans, while FBP detected 100 and 95 lesions on baseline and follow-up scans, respectively. Therefore, 17 more lesions were seen on IRSAC. The mean SUVmax values on baseline scans for FBP and IRSAC were systematically different, at 4.46±1.99 and 5.13±2.67, respectively. On follow-up scans values were 3.89±1.72 for FBP and 4.29±1.93 for IRSAC. Comparison of FBP with IRSAC on baseline and follow-up scans were statistically significant (baseline: paired "t"-test p=0.0017; follow-up: paired "t"-test p=0.0008). Phantom studies reveal that these differences can be explained by the type of reconstruction filters used, and IRSAC was more accurate than FBP. Conclusions. IRSAC detects smaller volumes in phantoms, patient images are easier to interpret and more metastatic lesions were detected. In addition, IRSAC provides reproducible quantitative data, comparable to data provided by FBP. IRSAC SUV and FBP SUV are in close agreement but there was a statistically significant difference between the two, and therefore threshold values of SUV will probably need to be re-determined with IRSAC, and are likely to be 10 to 19% higher than currently reported.
Editor: 
Rights: fechado
Identifier DOI: 
Address: http://www.scopus.com/inward/record.url?eid=2-s2.0-0036620677&partnerID=40&md5=538f19b5551d6c82329455af7056c9f2
Date Issue: 2002
Appears in Collections:Unicamp - Artigos e Outros Documentos

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.