Please use this identifier to cite or link to this item: http://repositorio.unicamp.br/jspui/handle/REPOSIP/100403
Type: Artigo de evento
Title: Use Of Column With Modified Silica For Interfering Retention In A Fia Spectrophotometric Method For Direct Determination Of Vitamin C In Medicine
Author: Fernandes J.C.B.
Neto G.D.O.
Kubota L.T.
Abstract: A flow injection system using a column packed with silica modified with aminopropyl groups as reactor in the spectrophotometric detection, at 265nm, was developed for l-ascorbic acid determination. The column packed (2.79 i.d. and 50mm length) with modified silica (200mg) was used to eliminate interference by ionic pair formation between amine groups and interfering compounds. An analytical frequency of 30 samples per hour, a detection limit of 2.0x10-6moll-1 and a linear response range between 1.0x10-5 and 1.0x10-4moll-1 were obtained in optimized conditions. The estimation of relative standard deviation was 1.5% (n=20) for a 5.0x10-5moll-1 ascorbic acid solution. The method was applied in medicine samples to determine ascorbic acid and the results were in agreement of the nominal values. Copyright (C) 1998 Elsevier Science B.V.
Editor: 
Rights: fechado
Identifier DOI: 10.1016/S0003-2670(97)00564-3
Address: http://www.scopus.com/inward/record.url?eid=2-s2.0-0032547005&partnerID=40&md5=735822ccc7af608578f3afb89f84213e
Date Issue: 1998
Appears in Collections:Unicamp - Artigos e Outros Documentos

Files in This Item:
File Description SizeFormat 
2-s2.0-0032547005.pdf338.44 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.